Tender For supply of repair and preventive maintenance of dg set ranchi oa - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva //bid details 2 / 35
Tender For providing of repair maintenance of dg set hazaribag - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva
Tender For providing of repair and maintenance of dg set under daltonganj - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva
Tender For corrigendum : tender for complete repair of different electronics modules or dc power supply cards of governor control panel and avr cards at 3x 1.5 mw thirot power house under the resident engineer, larji power house division hpsebl, thalout - tender for complete repair of different electronics modules/dc power supply cards of governor control panel and avr cards at 3x 1.5 mw thirot power house under the resident engineer, larji power house division hpsebl, thalout.’
Tender For corrigendum : provision of 01 x 30 kva genr with connected items as standby power requirements for sewage treatment plant under age (i) bhalra - supply, installing, commissioning and testing, water cooled, sound proof silent type, turbo charged, diesel engine driven generating set 30 kva (at 0.8 pf), 415v, 3 phase, 4 wire engine as per is: 10001/10002 and alterator as per is: 13364, complete with relay panel for automatic starting on mains failure, control panels having meters in an integral acoustic enclosure as per recommendation cpcb norms, comprising of the following:notes: quoted rates shall deemed to include the following also:-(i) supply of t and p and normal space ie., bi-hexagonal ring spanner set of 12 pieces - 01 set.(ii) fuel measuement gauge - 01 no, hand operated fuel lifting pump with steel pipe 40mm dia - 01 no, hydro meter - 01 no, set of fan belt, oil/ fuel filters initial filling of coolant (coolant-2liters).(iii) service maintenance manual along with cat part list and price list - 03 set each.(iv) make of engine and alternator will be got approved from age (i) bhalra before placing the order., (a) diesel engine. diesel engine developing suitable bhp, 1500 rpm inclusive of the following standard accessories:(i) radiator/ heat exchanger cooling system. (xiv) battery charging generator.(ii) spider coupling guard. (xv) industrial silencer.(iii) fly wheel. (xvi) lubricant oil cooler.(iv) fly wheel housing complete with starter gear ring and coupling. (xvii) flexible pipe for silencer. (v) fuel pipes. (xviii) battery volt meter.(vi) air cleaner. (xix) water temperature gauge, lub oil pressure (vii) fuel and lubricant oil filter. gauge.(viii) by pass filter. (xx) speedo meter and engine running hours meter.(ix) coolant inhibitor. (xxi) display for fault.(x) fuel pump. (xxii) turbo charger.(xi) water pump. (xii) lubricant oil pump.(xiii) self/electric starter.(b) alternator : synchronous alternator 3 phase 4 wire, 50 cycles 1500 rpm, self excited, self regulated, brushless type, 0.8 pf, 415v, ac supply, 30 kva capacity, copper wound, complete including necessary tools, mounted on strong rigid steel fabricated base frame and directly coupled through flexible coupling with diesel engine, complete all as specified and directed., (c) amf/ control panel : amf panel factory made of suitable capacity as per original equipment manufacturer make and specification or as approved by oem for dg set of capacity 30 kva of suitable size, indoor cubical type, front and back openable fabricated out of mild steel sheet 1.6mm thick grounted in floor with adequate pcc foundation and minimum consisting of following :(i) contactor of suitable size for 30 kva dg set.(ii) copper bus bar of suitable current rating and sensitivity relay set unit with auxiliary cts.(iii) electronic latch circuit with tripping indication.(iv) re-set facilities.(v) 3 phase mvr relay unit with single phase protection complete with 2 no nc auxiliary contacts.(vi) 3 phase avr relay unit complete.(vii) self sequential starting relay unit 12 volts dc complete with alarm and power contactor. (viii) electronic timer 220 volts for main contactor with 1 no nc auxiliary contactor.(ix) electronic timer 220 volts for fuel cut off operation with 1 no auxiliary contactor.(x) battery charging 2x12 volts 10 amp complete with digital voltmeter and amps meter, including trickle and boost charging, make : su-kam, amco, exide or any other make as recommended by the manufacturer.(xi) volt meter 0-500 volts panel mounting of size 96mm square with selector switch digital type.(xii) amps meter 0-100 amps with 3 nos cts, 400/5 and selector switch 96 mm square digital type.(xiii) frequency meter (45-55) hz, 415 volt, 96mm square digital type.(xiv) the amf panel should have manual by pass arrangement too in case of failure of amf panel., (d) fuel tank of capacity as per manufacturer recommendations.(e) base frame made out of suitable channel duly reinforced and provided with adequate nu
Tender For rewinding / repairing / rectification, re-installation and commissioning of buck/boost and avr unit with rq panel units of 33 kv transformer at office building gnida, greater noida.
Tender For tender for supervisory servicing overhauling checking and testing of 1500 kw jyoti make alternator , servicing overhauling checking and testing of 15kw dc exciter jyoti make , servicing checking testing of static excitation system make power tech engineer , servicing checking testing of acb 3200a land t make , servicing checking and testing and calibration of protection relay for acb and control panel for 1500kw jyoti make alternator , servicing checking and testing of tripping circuit between protection relay and acb for healthiness , servicing checking and testing and calibration of jyoti make avr for 1500kw alternator , checking and testing of rotor shoe bolts by torque wrench , drop test of main rotor for 1500kw jyoti make alternator.
Tender For tender for off season checking. inspection. overhouling. testing calibration and amc for crushing season 2025.26 for fibrizer acb.1600 amp capacity landt and havells make , off season checking. inspection. overhouling. testing calibration and amc for l and t make main panel acb capacity 4000 amp. and bus bar coupler acb , off season checking.overhouling.inspection.calibration and amc for crushing season 2025.26 for all protection relay of main pannel , off season checking. overhouling.inspection.calibration of 3750 kva of avr pannel with mode of. m.s kec make power alternator along with amc for crushing season 2025.26 , testing and calibration of metering system for 3mw kec alternator panel , dismantling and re alignment of 3000kw aec make alternator , charges for trouble shooting repairs , off season checking. testing.alternator earthing of main pannel earting system , supervision and overhaulingl and elecfrical testing of ac, exciter. along with rotating diodes for 3mw kec make alternator , off season checking inspection .overhauling .testing .calibration for crushing season 2025.26 supervisory. overhauling for 3000kw kec make alternator
Tender For supply of supply, fabrication and construction of copper plate earthing details of electrodes and earth pit at akashvani jaspur, uttarakhand , providing of 50mm x 3mm copper strip and interconnecting earth electrodes with fabrication and fixing of 50mm x 3mm copper strip at akashvani jaspur, uttarakhand , providing and fixing of nomenclature sign marker for earth pits at akashvani jaspur, uttarakhand , providing of 25 mm x 3 mm copper strip for extension of earthing system up to the transmitter hall, ups and lt panel at akashvani jaspur, uttarakhand , copper strip laying for extension of earthing system up to the xtr hall, ups and lt panel and terminating in bus bar by digging the soil and placing the copper strip along the trenches at air jaspur , providing of 375x38x6mm copper bus bar with insulators and steel nut bolts and the fixing of 375x38x6mm copper bus bar is to be done to terminate the different earthing system at akashvani jaspur , making of trenches of size 700mm x 750mm for 185 sq mm 3.5 core starting from state electricity transformer to lt panel by digging the soil which includes cement concrete interlocking tiles , providing and grouting of 2 nos. of 4inch dia g.i. pipes of different length on the cement concrete flooring, road, and cement concrete interlocking tiles and along the vertical walls. , unwinding roll of 185 sq. mm 3.5core al. cable from their cable drum and laying the cable through the trenches and through the g.i. pipes as laid down at akashvani jaspur , reconstructing the cement concrete interlocking tiles floor and repairing the area with cement concrete interlocking tiles and finishing the surface at akashvani jaspur , providing and fixing of lt cable route marker made up of 2.5inch dia signage with 10mm x 2ft long ms rod from transformer to lt panel at akashvani jaspur , providing and fabricating of overhead shed for the installed 62.5kva dg set as per drawing at akashvani jaspur supply, fabrication and construction of copper plate earthing details of electrodes & earth pit as per given below: digging of pit of size: 1 mtr x 1 mtr x 3.5 mtr(d) providing of copper plate size 600 x 600 x 3mm. providing of copper strip of 50x3mm shall be extended from bottom of the earth pit to the surface of the earth pit, after joining the copper strip by copper rivets and proper brazing of strip to the copper plate. providing and fixing the 10ft. long 38 mm dia class c g.i pipe of reputed make such as surya, jindal or similar and fixing with the copper plate in the center with g.i/ ss nut bolts class c. one g.i. reducer at the top of the pipe is to be provided for fixing steel mesh for watering as shown in the drawing. placing the copper plate with pipe and strip into the pit. providing & filling of 2 nos. of bags of bentonite each of 50 kg. (for each earth pit.) providing & filling of 80kg charcoal, and 80kg raw salt in alternate 3 to 4 layers in each earth pit. the fresh soil about 2.0 cubic metre in earth pit size in layers is to be arrange to fill the pit for proper result. proper watering of the filled pit for initial charging of pits. providing of heavy duty c.i. cover with lifting hooks. construction of cc chamber in ratio 1:4:8 & fixing of heavy duty c.i. cover., providing of 50mm x 3mm copper strip and interconnecting earth electrodes with fabrication & fixing of 50mm x 3mm copper strip as per given below: i. 2 grid out of 6 pits for transmitter. ii. 1 grid out of 3 pits for audio. iii. power supply-3 pits separate (lt electrical panel, ups & isolation transformer, avr) iv. rf //bid details 2 / 25